In partnership with

Protection that alerts the people you trust

When you use SABRE SMART 2.0, the free SABRE Personal Safety App instantly sends your live GPS location to up to five emergency contacts. Trusted formula, 10-second spray time, flip-top safety and a practice spray in the box.

Earth-covered ammunition bunkers ringed by sand barriers and water tanks on frosted Iowa farmland at dawn

THE READY BRIEF

Practical preparedness for uncertain times

FROM THE DESK

Generator run time depends on how much you ask of it. Champion's Amazon listing rates its 4,000-watt dual-fuel inverter at up to 10 hours on gasoline and up to 25 hours on propane. Those are best-case figures, and they shrink as the load grows. A refrigerator, a few LED lights and phone chargers draw a small fraction of what a whole house does. Today's issue covers how to size a generator to the loads you need.

THE BRIEF

Generator Sizing and Selection

A generator is one of the most impactful preparedness purchases you can make. It's also one of the most commonly mis-purchased. People either buy too small and can't run what they need, or buy too big and blow through fuel like it's free. Getting the sizing right starts with knowing what you need to power.

Start by listing your critical loads: the appliances and systems you need during an outage, not everything you want. A typical priority list includes: refrigerator (100 to 200 watts running, 1,200 watts starting surge), a few LED lights (10 to 20 watts each), phone and device charging (25 to 50 watts), and possibly a well pump (750 to 1,500 watts running, 2,000+ watts surge) or a furnace blower (300 to 500 watts).

Add the running watts of your critical loads. That's your baseline. Then check the highest starting surge among your loads, because motors in refrigerators, pumps, and compressors draw 2 to 3 times their running wattage for a few seconds when starting. Your generator needs to handle both the running total and the largest single surge.

For most households running critical loads only, a 3,000 to 5,000-watt generator covers the essentials. This range handles a fridge, lights, charging, and either a well pump or a window AC unit (not both simultaneously). If you need to run a furnace blower, a sump pump, and a refrigerator, size accordingly based on your actual loads.

Generator types break into three categories. Conventional open-frame generators ($300 to $800) are loud, heavy, and deliver raw power. They're workhorses for job sites but overkill for home backup. Inverter generators ($500 to $1,500) produce clean power safe for sensitive electronics, run quieter, and have better fuel efficiency at partial loads. For home preparedness, inverter generators are almost always the right choice. Dual-fuel generators run on gasoline or propane, giving you fuel flexibility.

Fuel type matters for preparedness. Gasoline is the most common but degrades in storage and may be unavailable during widespread outages. Propane stores indefinitely and is available when gas stations lose power, but propane generators produce slightly less power per BTU. Dual-fuel models offer the best flexibility: run on gas when available, switch to propane when gas stations are empty.

The Honda EU2200i and EU3000iS are widely used reference points for inverter generators, known for quiet running and fuel efficiency, and they cost more than most alternatives. Budget options from Westinghouse, Champion, Predator and WEN cost less. Read reviews from actual owners, not just spec sheets.

Safety is non-negotiable. Never run a generator indoors, in a garage, or in any enclosed or semi-enclosed space. Carbon monoxide from generator exhaust kills people every year during power outages. Run generators outside, at least 20 feet from the house, with the exhaust pointed away from windows and doors. A battery-operated CO detector inside your house is essential whenever a generator is running.

A transfer switch, installed by an electrician, connects the generator to your home's electrical panel safely. Without one, you run extension cords from the generator to individual appliances, which works but limits what you can power and creates trip hazards. A transfer switch lets you select which circuits receive generator power, including hardwired systems like well pumps and furnace blowers. Get a quote from a licensed electrician, since the cost depends on your panel and the number of circuits.

Maintenance between outages is what determines whether your generator starts when you need it. Run it under load for 15 to 30 minutes monthly. Use fresh fuel with stabilizer. Check the oil before each use. Replace the spark plug annually. A generator that sits for a year without running often won't start when the power goes out.

ONE THING TODAY

Calculate your critical load wattage.

Look up the wattage of your refrigerator, furnace blower, well pump (if applicable), and the lights and devices you'd need during an outage. Add the running watts. Note the highest surge wattage. Write it down. This number tells you exactly what size generator to shop for.

ON THE RADAR

Colorado's Digital ID App Is Offline After a Breach That May Reach Up to 150,000 People

Colorado took its myColorado app offline after an unauthorized user accessed data on the platform late Nov. 18, GovTech reported Nov. 24. The incident may have compromised data for 50,000 to 150,000 people, out of about 2.1 million users. Officials have not said what data was accessed or when the app will return, and the state will notify affected people when the investigation ends. The app holds mobile driver's licenses accepted at more than 250 airports, plus hunting and fishing licenses and vehicle registrations. Why it matters: a digital ID can fail the way the grid can, so carry the physical card as your backup. Watch for a restoration date and the notification letters.

Source: GovTech

LESSON FROM: MATTHEW STEIN

Matthew Stein is an MIT-trained mechanical engineer and author of When Technology Fails, a preparedness manual. A revised and expanded edition with Tim MacWelch is listed on Amazon at $32.56 in paperback, dated June 2, 2026. It treats power as one system among several, which fits this issue: a generator is one piece of a plan, not the plan.

Our takeaway for this issue: generator selection is a sizing problem. Add up the running watts of your critical loads, note the largest starting surge, add about 20% for margin, and buy that size. The goal is to keep critical functions running on as little fuel as possible, not to copy your normal electricity use during an outage.

WHAT'S HAPPENING

Army Detonates 5 Tons of Unstable Lead Azide in Iowa

The Army scheduled a controlled detonation of 68 drums of degraded lead azide, more than 9,700 pounds, at the Iowa Army Ammunition Plant in Middletown for about 9 a.m. CST Wednesday, Nov. 25, the Army said. In its crystallized state, lead azide is sensitive to friction, vibration, heat and shock. The Army ringed the bunkers with sand barriers about two stories high and water tanks, and recommended relocation within a five-mile cone southwest of the plant. The Illinois EPA says weather data show Illinois is not expected to be hit by the plume. If told to shelter in place: close windows and doors, set HVAC to recirculate, and wet-wipe surfaces afterward instead of dry sweeping.

Big plans? Pack a trusted companion.

Black Friday in the US and Canada: save up to US$90 or CA$115, respectively, on a new ZOLEO plus four months of prepaid service, with activation included. New trails ahead? Pack a way to stay connected beyond cell coverage. Exclusively at zoleo.com.

Savings include activation. Eligible new, never-activated ZOLEO 1500 devices in the US and Canada. Four consecutive months of prepaid service begin at activation. Payment method required; service then continues on the same-tier monthly plan at the then-current rate unless another option is selected. Taxes, add-ons and extra usage are additional. Terms apply.

WHAT WE'RE RECOMMENDING

About $740 on Amazon. Champion lists 4,000 starting watts and 3,000 running watts on gasoline (2,700 running watts on propane), up to 10 hours on gasoline and up to 25 hours on propane, and a CO Shield automatic shutoff. It is rated at 64 dBA from 23 feet. The dual-fuel design matters for preparedness: you can switch to propane when gas is hard to find.

Inverter output is clean enough for laptops and phones, and the 3-year warranty is listed on the product page.

Budget alternative: the Predator 3500 from Harbor Freight, roughly $600 to $800 depending on sales. Harbor Freight lists 3,000 running watts, up to 11 hours at 25% load and a CO Secure shutoff. It is a gasoline model, so there is no propane option.

OVERRATED / UNDERRATED

Overrated: Whole-house standby generators. They cost thousands of dollars installed and add convenience, but a well-sized portable generator handles critical loads for far less, with more fuel flexibility.

Underrated: Running a generator on a schedule instead of continuously. The CDC says a refrigerator keeps food safe for up to 4 hours without power if the door stays closed, and a full freezer for 48 hours. Running the generator for a couple of hours, then shutting it off, can stretch your fuel if you keep the doors closed.

COMING UP

Building community resilience. What organizing with your neighbors before a disaster looks like.

How was today's issue? Tap one below. If you pick "Could be better," tell us what to fix.

How was today's issue?

Login or Subscribe to participate

PS: Run your generator outdoors, more than 20 feet from windows, doors and vents, with a battery-powered CO detector inside. Do you know your critical loads in watts yet?

THE READY BRIEF is published for informational and educational purposes only. Nothing here is professional legal, medical, financial, or tactical advice. Preparedness looks different for every household. Use your own judgment, consult qualified professionals when the stakes are high, and adapt what you read here to your actual situation.